Parameter:Â
BJ4301
Output power
≥105w
Speed(r.p.m)Â
/
Oscillations (osc/min)
0-15000
Torque(Nm)
/
Operation(V) voltage
12
Sterilization
155°C
Swings (°)Â
/
Noise(db)
≤75
BJ4302
Output power
105w
Speed(r.p.m)Â
0-1100
Oscillations (osc/min)
/
Torque(Nm)
2.9
Operation(V) voltage
12
Sterilization
155°C
Swings (°)Â
/
Noise(db)
≤40
BJ4303B
Output power
≥90w
Speed(r.p.m)Â
0-630(Default)/0-1000(Customized)
Oscillations (osc/min)
/
Torque(Nm)
3.6
Operation(V) voltage
12
Sterilization
155°C
Swings (°)Â
/
Noise(db)
≤40
BJ4307B
Output power
≥90w
Speed(r.p.m)Â
0-300
Oscillations (osc/min)
/
Torque(Nm)
10
Operation(V) voltage
12
Sterilization
155°C
Swings (°)Â
/
Noise(db)
≤40
BJ4309
Output power
≥90w
Speed(r.p.m)Â
/
Oscillations (osc/min)
0-15000
Torque(Nm)
/
Operation(V) voltage
12
Sterilization
155°C
Swings (°)Â
/
Noise(db)
≤70
Notes:
1.Sterilize temperature ≤ 135 °C (Improved type ≤ 155 °C ),if the     temperature is over 135 ° C ,the motor will be damaged. 2.Normal bone drill can only hold drill bits less than 6mm,acetabulum     reaming drill with big torque,rpm is around 300,canulate drill is used     with nail or K wire ,rpm is around 600. 3.The battery need to be get out of the pwer tool after surgery. Otherwise     the small automatic discharge of the electric will make the life of the     battery short. 4.The battery cannot be sterilized ,it is not autoclavable. 5.The cranial bur must be washed right after the surgery by purger in     order to aviod the blood stick in the bur,then we should make it dry. 6.The battery space in the handpiece of the tool should not have any     water,after sterilization. 7.The cranial bur blade is made of medical stainless steel,in order to     avoid broken,so it is flexible and not very hard,it is easy to be attrite,     we suggest each blade only use for 1 surgery.
                          About us
      Established in 1993 and headquartered in Shanghai, Bojin, as an advanced orthopedic equipment
manufacturer and solutions provider, Bojin focuses on the development and marketing of orthopedic-purpose
motor products, X-ray imagescopes, treatment apparatus, and supporting surgical tools/parts. It has more than
one hundred types of orthopedic products under 8 series, which have received QC certification of 3C, ISO9001,
ISO13485, CE of the EU, and FDA Registry 3008787426. Its mission is to satisfy the needs of patients and
medical care with innovative high-tech products and therefore become a promoter of people's orthopedic health.
It has built a healthy sales and services network thanks to its 200 dedicated employees in the marketing
companies or teams in more than 4countries and regions across North America, Europe and Asia. Its products
are used in more than 60 countries and, in particular, in more than 20000 Chinese medical institutions 70%
of which are 3A-rated hospitals.
Â
Surgical Multi Function Power Tools Drill and Saw (System 4300)
Model NO.: BJ4300
Medical Devices Reg./Record No.: Hxzz20162100264
Application: for Joint in Orthpeadic Surgery
Main Material: Stainless Steel, Aluminium Alloy
Name: Orthopedic Power Tool
Color: Slivery
Battery: Rechargeable
Sterilization: Sterilized Case or Carton Case
Warraty: 2 Years
Package: Sterilzied Case or Carton Case
Trademark: Bojin and OEM
Transport Package: Aluminum Case and Carton
Specification: CE, FDA, ISO, SGS
Origin: Shanghai
HS Code: 90189090